| Keakuratan | Standar: hingga 0,05% |
|---|---|
| Suhu proses | -40°C...+110°C |
| Suhu nominal | -40~200℃ |
| Antarmuka komunikasi | Tergantung Pada Instrumen Tertentu |
| Kondisi | Baru |
| Process temperature(Standard) | -40 to +125 °C (-40 to +257 °F) |
|---|---|
| Process connections | Threaded, flange, hygienic, remote seal |
| Applications | hygienic, chemical, and oil & gas applications |
| Wetted materials | 316L stainless steel, Alloy C, Tantalum (optional) |
| Output signal | 4 to 20 mA with HART |
| Keluaran Alarm | Tidak ada aliran, alarm tinggi dan alarm rendah |
|---|---|
| Media Cairan | Udara, Air, Minyak, Gas |
| Diagnostik | Diagnostik Dasar, Peringatan Proses, Diagnostik Integritas Loop, Diagnostik Garis Impuls yang Ditega |
| Protokol komunikasi | 4-20 Ma Hart®, WirelessHart®, Foundation ™ Fieldbus, Profibus® PA, 1-5 V Low Power Hart® |
| Tingkat Pembaruan Nirkabel | 1 detik. hingga 60 menit, dapat dipilih pengguna |
| Merek | Guanghua |
|---|---|
| Presisi | ± 0,25% 、 ± 0,5% |
| Sinyal keluaran | Sistem dua kabel 4 ~ 20mA DC |
| Kelembaban lingkungan | 0 ~ 100% |
| Waktu pengiriman | 4-8 minggu |
| Nama produk | Fisher FIELDVUE DLC3010 DLC3020 DLC3020F Pengontrol Level Digital |
|---|---|
| Merek | Nelayan |
| Model | DLC3010 DLC3020 DLC3020F |
| Klasifikasi Area Berbahaya | Ex h IIC Tx Gb |
| Ketepatan | 0,15 |
| Kelembaban relatif ambient | ≤93% RH |
|---|---|
| Jenis koneksi | Flensa, benang |
| Sinyal kontrol | 4-20mA/0-10V |
| positioner | Opsional |
| Diameter nominal | DN15 - DN600 (½ ″ –24 ″) |
| Protokol komunikasi | 4-20 HATI |
|---|---|
| Kisaran Suhu Proses | Hingga 1300 °F (705 °C) atau 1922 °F (1050 °C) |
| Kisaran suhu sekitar | 40 hingga +149 °F (-40 hingga +65 °C) |
| Jenis pengukuran | Oksigen, Zirkonia - Disk Brazed |
| Ukuran | Opsi Panjang Probe dari 18 inci hingga 6 kaki |
| Jaminan | 3 tahun |
|---|---|
| Nomor model | DL3010 |
| Jenis pemasangan | Terpasang integral |
| Antarmuka data | kabel |
| Tekanan outlet maks | 145 psig |
| Process temperature(Standard) | -40 to +125 °C (-40 to +257 °F) |
|---|---|
| Process connections | Threaded, flange, hygienic, remote seal |
| Applications | hygienic, chemical, and oil & gas applications |
| Wetted materials | 316L stainless steel, Alloy C, Tantalum (optional) |
| Output signal | 4 to 20 mA with HART |
| Protokol komunikasi | 4-20 HATI |
|---|---|
| Kisaran Suhu Proses | Hingga 1300 °F (705 °C) atau 1922 °F (1050 °C) |
| Kisaran suhu sekitar | 40 hingga +149 °F (-40 hingga +65 °C) |
| Jenis pengukuran | Oksigen, Zirkonia - Disk Brazed |
| Ukuran | Opsi Panjang Probe dari 18 inci hingga 6 kaki |