Ametek Thermox WDG-V WDG-IV UOP UOP/RP Continuous Catalyst Regeneration Oxygen Analyzer for UOP Process

1
MOQ
US $99999.00 - 105000.00/ Unit
harga
Ametek Thermox WDG-V WDG-IV UOP UOP/RP Continuous Catalyst Regeneration Oxygen Analyzer for UOP Process
fitur Galeri Deskripsi Produk Quote request suatu
fitur
Spesifikasi
Rentang output: Dari 0-1% hingga 0-100%
Peringkat Kontak: 0.5a, 30v, 10va maks. Beban non-induktif, AC atau DC
Lampiran: IP65 (NEMA 4X)
Suhu sekitar: -20 hingga 55 ° C (-4 hingga 131 ° F)
Ketepatan: ± 0,75% dari nilai yang diukur atau ± 0,05% oksigen, mana yang lebih besar
Keluaran: 4-20 ma / hart
Informasi dasar
Nama merek: Ametek
Nomor model: WDG-V UOP/WDG-IV UOP
Syarat-syarat pembayaran & pengiriman
Kemasan rincian: Seperti yang diminta
Waktu pengiriman: 60 Hari
Syarat-syarat pembayaran: T/T
Menyediakan kemampuan: 50 unit per tahun
Deskripsi Produk
Ametek WDG-V UOP & WDG-IV UOP

The oxygen analyzers that every UOP CCR Platforming unit has on the regen tower stack

Why UOP Only Allows These Two Models

When you license a UOP CCR Platforming process, the P&ID already shows an Ametek WDG analyzer on the regenerator flue gas. That’s it – no alternatives. The reason is simple: the sensor sits directly in 650–720 °C flue gas full of chlorine, catalyst dust and water. Normal “cold-wall" analyzers die in weeks. The WDG-V UOP (newer) and WDG-IV UOP (old workhorse) are built different – the zirconia cell is close-coupled, the whole probe is heated to 300 °C, and the blowback actually works. Most units get a cell change every 4–6 years and keep running.

Stuff That Actually Matters on a CCR Unit
  • Close-coupled sensor – no sample line to plug with cat fines
  • Whole probe heated to 300 °C – no acid condensation
  • Real automatic blowback every few hours – keeps the filter clean
  • WDG-V UOP has color touchscreen and USB data log
  • WDG-IV UOP still preferred by old-timers because it never breaks
  • Both give 0–1% and 0–10% O₂ ranges for burn and combustion control
Quick Numbers
Measurement 0–1% / 0–10% O₂ (field selectable)
Process temperature up to 900 °C (normal 650–720 °C)
Response time T90 less than 10 seconds
Output 4–20 mA isolated, Modbus RTU, HART on WDG-V
Power 115/230 VAC, about 500 W with heater
Probe length 0.5 m – 3 m (most plants use 1.5 m)
Approvals Class I Div 2, ATEX Zone 2 standard
Where They Live
  • UOP CCR Platforming regenerator flue gas
  • Some Axens and ExxonMobil CCR units also specify them
  • Chlorine-rich combustion zones in catalyst plants
Questions We Hear on Every Turnaround

Q: How often do I change the zirconia cell?
A: Usually 4–6 years, some plants hit 8 years.

Q: Can I just buy any zirconia analyzer?
A: No – UOP will reject it during HAZOP if it’s not WDG-IV/V UOP.

Q: Spare parts for the old WDG-IV?
A: Still made in USA, next-day ship from stock.

Contact Us

Ametek Thermox
Email: edwardzhao@gbsxj.com

Phone/WhatsApp/WeChat: +8615000725058

Other Stuff We Sell for Refineries
  • WDG-V Zone 1 version for worse locations
  • WDG-Insitu for boiler combustion
  • Replacement cells and filters for old WDG-IV